2011

Table Of Contents
Drawing Audit identifies and cleans up some of the problems that can affect
an AutoCAD Electrical drawing. Save the error report file for reference or surf
the file to view and correct errors.
Specifies to run the audit on the active drawing or selected
drawings in the active project.
Audit drawing or project
Redisplays the last audit report that was run. You can then
surf to the performed function, save the report, or print
the report for reference.
Previous
Goes to the error location within the drawing where the
error occurred and was fixed.
Surf
After you click OK, you can select the type of drawing audit to run. If you selected to audit the
project, select the drawings in the active project to audit, and click OK.
Looks for problems related to missing wires which were
connected through gap pointers. Also see
Check / Repair
Gap Pointers on page 1688.
Wire gap pointers
Looks for and cleans up wires pointing to nonexistent wire
numbers (it is the opposite of wire number floaters). Also
looks for bad color/gauge label pointers.
Bogus wire number and color/gauge
label pointers
Looks for and erases zero length line entities on the wire
layer.
Zero length wires
Looks for and erases wire numbers that are not linked to a
wire network (for example, the wire was manually erased
but wire number remains).
Wire number floaters
Draws an outline around each wire entity.Show wires (mark in red)
Bright red outline - regular wires
Magenta outline - wires on layers defined as No Wire
Numbering.
(Available when running on the active drawing only.)
Overview of real-time error checking | 1693