Toolbar: Schematic Reports
Menu: Projects Reports Electrical Audit
Command entry: AEAUDIT
When you run Electrical Audit, a progress bar shows the progress of the audit
process. Once the audit is complete, a text box displays the total number of
errors found. The Details option lists the detected problems. You can go to
the location of an error within the project and correct the error.
Displays the audit information for all the drawings in the
active project.
Project
Displays the audit information for the active drawing only.
If a different drawing becomes active, the display updates
Active Drawing
for that drawing. If the active drawing is not part of the
project, the Active Drawing control is disabled and the
Project control is selected.
Displays the unconnected wires for the active project. The
report lists the unconnected wire number, location point,
Wire - No Connection
error message, and the drawing where the error occurs. If
there is not a record of a wire number, the wire number
column is blank.
Displays missing or duplicated wire numbers for the active
project. The report lists the duplicated wire number, error
Wire Exception
message, and the drawing where the error occurs. If a wire
number is missing, the wire number column is blank.