Click Project tab Troubleshooting panel Command Trace drop-down
Command Trace Off.
Check, repair, or trace wire and gap pointers
The Check/Repair Gap Pointers utility verifies that the invisible Xdata pointers
on both sides of a wire gap/loop are valid. If not, appropriate pointers are
established. The Check/Trace a Wire utility single steps through and highlights
each connected wire of the selected wire network.
Check/repair wire gaps
Use this utility to create wire number jumps (on the current drawing) without
resorting to individual signal source/destination arrow symbols.
1 Click Schematic tab Edit Wires/Wire Numbers panel
Modify Wire Gap drop-down Check/Repair Gap Pointers.
2 Click the Check/Repair Gap Pointers tool.
3 Select each wire segment as directed.
Gap data is added as needed. The result of the check/repair is shown in
the command prompt area.
Check/trace a wire
Troubleshoot problems with unconnected or shorted wires and invalid wire
crossing gap pointers.