2011

Table Of Contents
Miscellaneous Tools
Overview of power check tools
You can add information to your schematic components to indicate power
source and load values using the supplied Power Check tools. Once these values
are added, you can run the Power Load Check Report to scan the wire
interconnections and report if there is too much load on a given power source.
There are 3 tools to use for checking power source/load:
Marks a component with a power source and load
value. The value is added to an AutoCAD Electrical
Add/Edit Power Source/Load Levels
connection attribute. This dialog box contains a list
of available connection points. If you select near the
connection point for the power value it is preselected
in the dialog box. Enter the power source and load
value and an optional units value. These values are
saved on the connection point as invisible xdata.
Marks a component with a PASSPWR flag. The
PASSPWR flag instructs the Power Report to pass
Set Pass Power
through the marked component when calculating
the load on a given source. If a component carries
the PASSPWR flag the Power Report program passes
through the component and continue looking for
load values on the network
Looks for any components assigned as a power
source and then follows any wires connected to that
Power Load Check Report
terminal. When a load is hit, it stops reading on that
wire segment and does not search past the load. For
22
1667