2011

Table Of Contents
NOTE You cannot see the command window messages during conversion unless
you turn on the
command trace mode on page 1686 debug tool.
Ribbon: Conversion Tools tab Tools panel Promis·e Conversion.
Toolbar: Conversion Tools
Menu: Projects Conversion Tools Promis·e Conversion
Command entry: AEP2E
Select Convert promis·e Project and click OK. Select the promis·e mapping
file and click Open.
promis·e Projects
Lists the promis·e projects defined in the project mapping
file.
Project Names
Lists the installation codes defined in the project installation
mapping file and the number of selected drawings.
Installation Codes
The drawing count shows the number of drawings in the selected promis·e
Project.
AutoCAD Electrical Project
Uses replaceable parameters to name projects (%P),
installations (%I), drawing file names (%S), and
Naming (Project, Installation, Drawing)
folders. Replaceable parameters take on the values
from the promis·e mapping files, however you can
add additional characters.
Specifies pre- and post-processing script files to run
against the entire project, and the AutoCAD Electrical
Conversion Setup
support files to use (Default_wdtitle.wdl and De-
fault.wdt). After you select the desired support file,
it is renamed and placed in the same folder as the
new project definition file (*.WDP). You also have
1640 | Chapter 21 Conversion Tools