2011

Table Of Contents
Default
Displays a dialog box to set the drawing-wide default assignments for each of
the four level categories. Values entered here become the default level
assignments for all unassigned panel layout footprint component and terminal
strip representations on the active drawing.
NOTE This dialog box can also be accessed from the Panel Configuration dialog
box.
Enter the optional 3-digit level codes (for example, 001, 002, and so on) for
one or more of the four level categories. For example, if everything on the
active drawing is in the fourth cubical of the second unit, and all of this is
part of the first shipping split section, enter 004 for level category 2 (for
example, cubical), 002 for level category 3 (for example, unit), and 001 for
level category 4 (for example, highest category shipping section). With these
defaults in place only the lowest level category 1 must be assigned on an
individual panel terminal strip basis.
Level 4/Level 3/Level 2/Level 1
Shows the level code assigned to each of the four level categories, Level 4 =
shipping split (highest level), Level 3 = unit, Level 2 = cubical, and Level 1 =
pan/plate (lowest level). The level code assignments should be 3-digit values
and chosen with the idea that their sort order on a per-level category basis
influences the actual inter-level wire sequence calculation.
The List button for each level category displays a dialog box showing the level
combinations that are assigned so far. Picking from this dialog box assigns
those same level category assignments to the currently edited panel layout
footprint. If codes are not defined in the edit boxes, the drawing-wide default
values displayed in the left-hand column of non-editable edit boxes are used
(if defined).
Level code/location
Controls whether the Level 1 edit box displays the 3-digit level code assignment
or the LOC attribute value of the device. This location display mode is for
display purpose only. The underlying 3-digit Level 1 code is always used for
the sorting installation.
Pick
Selects another panel layout footprint symbol or terminal strip representation
on the active drawing and copies its settings over to the currently edited
component
Insert/edit panel level assignment: component | 1621