Disable (Default) AutoCAD Electrical treats the
terminal connections through the terminal strip
normally. It uses the level category code assign-
ments of the terminal to influence how the
from/to wire sequencing is calculated.
Enable Processes the connection calculations of
the terminal last. It checks each of the terminal
potentials of the strip against those on any sup-
plementary terminal strip found that is at the
same level combination. For each potential
match, it attempts to make the from/to calcula-
tion for that terminal to be a simple jumper as-
signment from the terminal strip's terminal up
to the supplementary terminal strip. When a
match is not found, the from/to calculation
through the terminal strip operates in a normal
fashion.
Selects the footprint representation on the drawing
to copy the leveling code from.
Pick
Insert panel wiring diagram terminal strip
representation
Insert panel wiring diagram terminal strip
representation
Define a rectangle as a supplementary terminal strip to use in the wiring
routing information over large control system equipment.
Toolbar: Panel Level/Sequencing
Menu: Panel Layout Panel Level/Sequencing Insert Terminal Strip
Representation
Command entry: AETERMINALSTRIP
Inserts a terminal strip with just the tag of the com-
ponent, description text, and so on.
Use generic marker only
1614 | Chapter 19 Panel Layout