WDLEV or as extended entity data (xdata) on the symbol if the
target attribute is not available.
Copy level assignments
Copy level assignments
Define or capture a common set of level assignments for panel footprint
components and then copy these 3-digit level codes to one or multiple
footprints. This coding, when present, influences the way that AutoCAD
Electrical calculates the wire connection from/to sequence. As it processes the
schematic component representations and wiring, it checks for any coding
found on the panel footprint and panel terminal strip representations. When
present, it adjusts the from/to sequencing accordingly.
Toolbar: Panel Level/Sequencing
Menu: Panel Layout Panel Level/Sequencing Copy Level
Assignments
Command entry: AECOPYLEVEL
You can type in the level assignments or select from
the drawing using Pick. Categories: Level 4 (shipping
Level 4/Level 3/Level 2/Level 1
split - highest level), Level 3 (unit), Level 2 (cubical),
and Level 1 (pan or plate - lowest level). You can
copy all level information or unselect one or more
level categories before copying.
An enabled, blank edit box indicates to erase any
existing values and forces the use of the drawing-
wide default value. If an edit box is unavailable, the
existing value is not overwritten. Use the switches to
enable or disable the edit box for each level category.
Applicable only the level assignments to copy to
panel terminal strip representations, and the terminal
Terminal strips only
strips are referenced on the schematics as well as the
panel layout drawing. (In other words, they are not
supplementary terminal strips that are only represen-
ted on the panel layout drawings).
Select this option, and then select one of the follow-
ing:
Copy level assignments | 1613