View/edit panel component connection sequence
View/edit panel component connection sequence
This tool allows you to view and rearrange the sequencing of all panel footprint
components that share a common set of Level 1-4 level code assignments.
This coding, when present, influences the way that AutoCAD Electrical
calculates the wire connection from/to sequence. As it processes the schematic
component representations and wiring, it checks for any coding found on the
panel footprint and panel terminal strip representations. When present, it
adjusts the from/to sequencing accordingly.
NOTE Leveling is required before assigning sequencing on the panel footprints.
Toolbar: Panel Level/Sequencing
Menu: Panel Layout Panel Level/Sequencing View/Edit Component
Sequence
Command entry: AEVIEWCOMPSEQ
Select a footprint with a set of level codes assigned to it.
The components that have level codes matching the picked footprint are
displayed in the list box in the order they are inserted. It includes panel
footprint components that might appear on drawings other than the active
drawing (marked with "*" in the list). To modify the order, select an entry in
the list, then select Move Up or Move Down in the list. Multiple selection is
supported.
Moves the selected components up one spot in the list.Move Up
Moves the selected components down one spot in the list.Move Down
Defines the sequence by actual picks at each component. Pick
near each component in the order of how you want the sequence
Pick Mode
to proceed from component to component. Picking is limited to
components on the active drawing.
Removes the component sequence information from all listed
components.
Remove All
Saves the sequence assignments and writes them out to the
panel footprint representations. The data is stored on attribute
OK-new
1612 | Chapter 19 Panel Layout