2011

Table Of Contents
Equivalent of "%L%1:%P" (tag:term)%5
Equivalent of "%L%1:%P:%D" (tag:term:termdesc)%6
Equivalent of "%I%I%1" (INST prefix+IEC component tag)%7
Equivalent of "%I%L%1:%P" (tag:term)%8
Equivalent of "%I%L%1:%P:%D" (tag:term:termdesc)%9
The part after the ":" is suppressed if the value is blank in %2 - %9 parameters.
For example, %2=comp tag:term. The ":term" part is suppressed if blank.
Schematic layout wire connection annotation
Defines the wire connection text format.
Ribbon: Panel tab Insert Component Footprints panel Wire
Annotation.
Toolbar: Panel Layout
Menu: Panel Layout Wire Annotation of Panel Footprint
Command entry: AEWIREANNOTATION
Make your selections and click OK.
NOTE You can build two sets of panel footprint symbols: one set that does not
carry the target attributes for wire information and a set that does. When you
insert your panel symbols from the schematic extract, select Use Footprint Tables
to access the first set of symbols or select Use Wiring Diagram Tables to access the
second set.
Format
There are two format edit boxes on the dialog box. The "Full" format is used
if the target attributes are not found and MText is inserted. The "Partial" format
is used if the target attributes are found (described later). Each format uses
parameters that are then replaced with the specific wire information. AutoCAD
Electrical provides some predefined formats for you to select from the list box
1590 | Chapter 19 Panel Layout