2011

Table Of Contents
MText
The default MText insertion point is the same as the insertion point of the
footprint block. The default text size either matches that of existing wire
number attributes found on the footprint symbol or, if none present, the
MText size is forced to match the current value of the AutoCAD system variable
"TEXTSIZE".
To predefine the MText insertion point, text size, and text style on footprint
blocks, insert an invisible attribute "WXREF" on your footprint block library
symbol. Open up each footprint symbol in AutoCAD and insert a blank
attribute definition "WXREF". Put its origin at the point where you want
AutoCAD Electrical to insert the MText wire connection information. Mark
this attribute definition invisible and set its text size and style to the desired
MText size and style.
Add wire information to footprints
Inserts schematic wire connection information on to panel footprint
representations.
After you add wire numbers to your schematics, annotate panel footprint
symbols with this information. You can build panel footprint symbols with
target attributes used for the wire connection information. If these attributes
are not present on the panel footprint, a new or updated MTEXT entity displays
the wire information.
1 Click Panel tab Insert Component Footprints panel Wire
Annotation.
2 Specify to export the data for the active drawing or the entire project and
click OK.
Add wire information to footprints | 1587