%W and %1 and %G parameters. Acceptable formats include "%T=%W (%1)
%G" or "%T=%W / %1 (%G)" or "%T=%W (%1) %G".
NOTE You cannot use commas in the format. They signal multiple wire connection
annotations onto a single wire connection attribute.
Additional options for the "To" component tag
Additional options to include in the text.
Adds the terminal text as a suffix.Add terminal pin as a suffix to tag
Adds any terminal description value as a suffix.Add terminal description to tag
Adds any installation value as a prefix.Include installation prefix to IEC tag
format
View/Test
Allows a preview or test of the report.
Suppress any duplicated annotation on each terminal
Indicates to hide duplicated annotations so that they do not show on the
report.
Relationship between schematic drawings and
panel layouts
Automatic schematic/panel update
AutoCAD Electrical provides bi-directional updating between schematic
components and the associated footprint blocks. The link is through the
common tag identifier, for example, schematic relay coil, CR406, links to the
panel layout footprint that carries a CR406 tag value.
Bi-directional updates follow these rules:
Edits to a schematic parent update associated schematic child symbols,
panel footprints, nameplates, and peer one-line symbols.
Relationship between schematic drawings and panel layouts | 1531