2011

Table Of Contents
Menu: Panel Layout Panel Configuration
Command entry: AEPANELCONFIG
Panel Configuration saves settings as attribute values on a non-visible block
named WD_PNLM. In any panel layout command, if this block is not present
in the current drawing a message box displays asking permission to insert the
block. The location of the block is not critical.
Item Numbering
Specifies the number/letter to use as the first item number. AutoCAD Electrical
manages item number, drawing-wide, or project-wide (over many drawings),
so that the same number is always applied to identical components.
Balloon
Opens a subdialog box for setting the type of balloon marker (circle, ellipse,
polygon, text), marker size, margin, and text gap.
Footprint layers
Opens the Panel Component Layers subdialog box for setting the panel
component layers, non-text graphic layers, and nameplate layers. Panel
footprint layering works in the same way AutoCAD Electrical schematic
layering. When AutoCAD Electrical inserts a footprint, it is modified on the
fly to match the layering scheme set up in this dialog box.
Wiring level defaults
Sets the optional 3-digit wiring level codes. They are applied as defaults when
codes are not defined on panel layout components or terminal strip
representations. Preferred wire connection sequence follows this level and
numeric-code-within-level hierarchy.
Default spacing for multiple inserts
Specifies the x and y distance spacing for multiple footprint inserts.
Footprint insert
Specifies the default insert scale for panel footprint symbols. Also specifies
whether to insert the attribute template drawings and the scale to use.
You can set up to have visible attributes added to any footprint automatically
at footprint insertion time. Using non-intelligent footprint representations
1528 | Chapter 19 Panel Layout