Minimum attribute/Xdata requirements
The following tables are the minimum requirements for AutoCAD Electrical
to recognize a block as a panel footprint, terminal, or nameplate.
Component footprint - block must carry a minimum of one of the following:
VIA_WD_FPXdata name
FP (blank value)Attribute
P_TAG1 (and no attribute NP present)Attribute
Terminal footprint - block must carry a minimum of one of the following:
VIA_WD_FPTXdata name
FPT (blank value)Attribute
Panel nameplate - block must carry a minimum of one of the following:
VIA_WD_NPXdata name
NP (blank value)Attribute
Select Xdata to change to a block attribute
This tool converts any piece of invisible extended entity data (Xdata) into a
visible attribute tied directly to the footprint block.
Ribbon: Panel tab Other Tools panel Panel Configuration
drop-down Make Xdata Visible.
Toolbar: Edit Footprint Component
Menu: Panel Layout Make Xdata Visible
Command entry: AESHOWXDATA
Select a footprint.
After you click Insert, the dialog box disappears. Click the location for the
attribute. The attribute inserts, is linked to the footprint block, and the dialog
1526 | Chapter 19 Panel Layout