2011

Table Of Contents
name listed here, AutoCAD Electrical uses that attribute to carry the specific
piece of data. Otherwise, AutoCAD Electrical uses extended entity data with
names based on the data names listed here but with a VIA_WD_ prefix (ex:
"VIA_WD_DESC1").
identifies block as a component footprintFP
identifies block as a terminal footprintFPT
identifies block as a nameplateNP
panel component tag (used on component footprints and nameplates)P_TAG1
description line 1 - 3 (60 char max)DESC1-3
item/detail numberP_ITEM
optional attribute with a value of 1 indicates the item number is fixedITEM_FLAG
manufacturer name (24 char max)MFG
catalog number (60 char max)CAT
optional assembly codeASSYCODE
installation code (24 char max)INST
location code (16 char max)LOC
mount location code (24 char max)MOUNT
group location code (24 char max)GROUPWITH
schematic symbol block name (used for catalog lookup)WDBLKNAM
rating values (60 char max each)RATING1-12
terminal strip ID (terminal footprints only)P_TAGSTRIP
terminal number (terminal footprints only)TERM
wire number (terminal footprints only)WIRENO