2011

Table Of Contents
Panel Reports
Generate panel reports
AutoCAD Electrical has multiple panel reports that you can run.
Bill of Material report
This report parallels the Schematic BOM report, but deals with panel
component and terminal footprint symbols and nameplates. Optionally, it
can include schematic items that are not referenced on the panel layouts (for
example, field devices). You can customize the scope of the report by filtering
on certain location values (for example, report for CAB1 items only), process
only a subset of drawings, or include/exclude certain categories of items. The
report displays and tallies like items (for example, same part number) together.
Those with extra subassembly items are shown with a SUB multiplier value.
Component report
This report lists every occurrence of a smart panel component footprint found
on the current drawing or in the project drawing set. You can customize the
scope of the report by filtering on certain location values (for example, report
for CAB1 items only), process only a subset of drawings, or include/exclude
certain categories of items. Each extracted panel component is listed as its
own line item. If it has a part number that results in subassembly part numbers,
or has been individually annotated with multi-BOM part numbers, each
additional part number is a line item right below the main line item.
NOTE This report will not include panel terminals unless you check that option.
Nameplate report
This report is similar to the panel component report, but filters out all but
nameplate symbols.
Wire Connection report
Wire connection reports, extracted from the schematic wiring diagrams, can
be formatted and inserted next to panel footprint symbols as simple wiring
tables. AutoCAD Electrical extracts and formats a small report of wire
connection information for the selected components, referencing the wire
extract file. If your footprint symbols carry the AutoCAD Electrical X?TERMxx
Panel Reports | 1427