This report scans the selected drawings and returns information about any
components connected to PLC I/O points. Data for the report starts at each
wire connection point and follows the connected wire. The first terminal
symbol, fuse symbol, or connector symbol that is hit reports in the column
marked with default "TERMTAG" label. The first schematic component reports
in the column with the "CMPTAG" label. If there are multiple instances, the
one closest to the PLC I/O point is the one that shows up in the report column.
Ribbon: Reports tab Schematic panel Reports.
Toolbar: Main Electrical 2
Menu: Projects Reports Schematic Reports
Command entry: AESCHEMATICREPORT
Select PLC I/O Component Connection from the report list.
Specify whether to process the project or the active drawing.
Installation Codes to Extract
Extracts only the information for components with specific installation values.
Indicate to process all components that carry part number values, components
without an installation code, or only components marked with a location
code that matches that entered in the edit box. Wild-cards are supported.
Once you pick Named Installation, type the installation code in the box or
click List: Drawing or List: Project to select from a list of used installation
codes. You can also create a report from multiple installation codes. AutoCAD
Electrical automatically creates a comma-delimited list for the named
installation search.
Location Codes to Extract
Extracts only the information for components with specific location values.
Indicate to process all components that carry part number values, components
without a location code, or only components marked with a location code
that matches that entered in the edit box. For example, BOM report for
components marked "OP STA 2". Wild-cards are supported.
Once you pick Named Location, type the location code in the box or click
List: Drawing or List: Project to select from a list of used location codes. You
1408 | Chapter 18 Reports