2011

Table Of Contents
Component report
This report performs a project-wide extract of all components found on your
wiring diagram set. This data includes component tags, location codes, location
reference, description text, ratings, catalog information, and block names.
Wire From/To report
If you marked components and/or terminals with location codes, you can
make good use of this report. This report first extracts component, terminal,
location code, and wire connection information from every drawing in the
project set. Then it displays a location list dialog box where you can make
your report's "from" and "to" location selections. All the location codes
AutoCAD Electrical found on the drawing set are listed on each side of this
dialog box. Location "(??)" is also included in the list if AutoCAD Electrical
found any component or stand-alone terminal that did not have an assigned
location code.
Component Wire List report
This report extracts the component wire connection data and displays it in a
dialog box. Each entry shows a connection to a component, the wire number,
component tag name, terminal pin number, component location code (if
present), and the layer that the connected wire is on.
Connector Plug report
This report extracts plug/jack connection reports and optionally generates pin
charts. Since each wire tied to each connector pin displays in the report, each
pin has two entries. One entry is for the 'in' wire and the other is for the 'out'
wire. To create a more useful report, select the PIN chart 'on' radio button at
the bottom of the Report Generator dialog box. Make sure the Remove
duplicated pin numbers toggle is checked and click OK. It reformats the report
so each pin is listed only once.
PLC I/O Address and Description report
This report lists each PLC module and its beginning and ending I/O address
numbers. It scans your drawing set and returns all individual I/O connection
points it finds. It includes up to five lines of description text and the connected
wire number for each I/O point.
PLC I/O Component Connection report
This report scans the selected drawings and returns information about any
components connected to PLC I/O points. Data for the report starts at each
1400 | Chapter 18 Reports