Overview of the catalog database table structure
AutoCAD Electrical uses the first 16 fields for its own which includes three
user fields for your use. You can insert additional fields beyond the 16th one,
but they are ignored when generating reports. Here are the 16 fields accessed
by AutoCAD Electrical. (They must remain in this order in the database
records.)
DescriptionWidthField Name
Catalog number.60CATALOG
Manufacturer code; abbreviations are allowed.24MANUFACTURER
Generic description.150DESCRIPTION
Generic type (field name varies based on table
name).
100TYPE
Generic rating (field name varies based on table
name).
100RATING
First miscellaneous text field (header cell is based
on the component family).
100MISCELLANEOUS1
Second miscellaneous text field (header cell is
based on the component family).
100MISCELLANEOUS2
Code to flag that this item has subassembly
items. Use a unique name code to link this main
60ASSEMBLYCODE
catalog item with other subassembly items.
Spaces are allowed.
Code to flag as a subassembly item of a main
item.
24ASSEMBLYLIST
Subassembly quantity (blank = quantity of 1).8ASSEMBLYQUANTITY
Field #1 for other information.100USER1
Field #2 for other information.100USER2
Field #3 for other information.100USER3
1274 | Chapter 17 BOM and Catalogs