2011

Table Of Contents
Renumbers ladder references project-wide.
Ribbon: Schematic tab Edit Wires/Wire Numbers panel Modify
Ladder drop-down Renumber Ladder Reference.
Toolbar: Ladders
Menu: Wires Ladders Renumber Ladder Reference
Command entry: AERENUMBERLADDER
Enter the first ladder line reference number.1st drawing, 1st ladder, 1st line ref-
erence number
Select an option for ladders on subsequent drawings.2nd drawing and beyond
Use next sequential reference - increment from the last
line reference on the previous drawing.
Skip, drawing to drawing count - enter an amount to
skip for the first ladder reference of the next drawing.
Project-wide update or retag
Project-wide update or retag
Resequences or updates component tags, wire numbers, cross references, signal
references, select drawing properties, ladders, and title blocks.
Ribbon: Project tab Project Tools panel Update/Retag.
Toolbar: Project
Menu: Projects Project-Wide Update/Retag
Command entry: AEPROJUPDATE
In one command, modify drawing properties and sheet values, renumber
ladders, retag components, redo cross referencing, and update title blocks.
1196 | Chapter 15 Project-Wide Tools