2011

Table Of Contents
Internally jumper the levels currently selected in the grid.
Delete the internal jumper currently assigned to the levels selected in
the grid
Clears all terminal block properties.Clear
NOTE Properties for a level cannot be cleared if there is a schematic
terminal representing that level (other than the terminal being edited),
or there is an external jumper on that level.
Terminal block property attributes
The values in the grid are stored as follows. The nn represents the level
number and is always stored as two digits (that is, 01, 02, and so on):
AttributeData
LnnLABELLevel Description (60 characters maximum)
LnnWIREPERCWires Per Connection (three characters maximum)
LnnPINLPin Left (12 characters maximum)
LnnPINRPin Right (12 characters maximum)
LnnINJUMPInternal Jumper
(255 characters maximum)
NOTE If these attributes are not present, the data is placed into Xdata with the
same name, only with a VIA_WD_ prefix.
Edit terminal
Edits individual terminals/levels.
Ribbon: Panel tab Terminal Footprints panel Editor.
1098 | Chapter 13 Terminal Tools