2011

Table Of Contents
Specifies the terminal number. If there is not PIN-
LIST information, the < and > buttons increment
Number
or decrement the terminal number. You can also
click Pick to select a text object or an attribute on
the active drawing to use for the terminal number.
When inserting a new terminal, the highest terminal
number in the strip is identified and the default
terminal number for the new terminal increments
by 1.
NOTE This is unavailable when the terminal symbol
does not have a TERM01 attribute or when the
terminal number is the same as the wire number.
Modify Properties/Associations
These controls support associations between schematic terminal symbols and
their panel terminal footprint or between multiple schematic terminal symbols.
There are certain conditions that you cannot associate terminals using the
Modify Properties/Associations options:
The drawing is not part of the active project.
You are using the Insert Terminal (Panel List) tool. However, once you exit
the Insert Terminal (Panel List) tool and the terminal is inserted onto the
drawing, you can modify the associations using these tools.
The terminals were inserted by the Terminal Strip Editor tool.
The terminals are one-line terminal symbols.
Displays the Add/Modify Associations dialog box
where you can select terminal strips and their re-
Add/Modify
spective blocks to make an association to the ter-
minal symbol being inserted or edited.
NOTE It is disabled if the active drawing is not part
of the active project.
Selects another terminal symbol on the active
drawing to associate to. You can select only one
terminal symbol to make the association.
Pick
1042 | Chapter 13 Terminal Tools