Edit Component
Ribbon: Schematic tab Edit Components panel Edit Components
drop-down Edit.
Toolbar: Main Electrical
Menu: Components Edit Component
Command entry: AEEDITCOMPONENT
Select the terminal to edit.
Terminal
These controls determine the overall tagging of the terminal block in the
project. The Installation, Location, and Tag Strip values define which strip
the terminal belongs to. The symbol block file name displays at the top of the
Terminal group.
NOTE Assign short installation or location codes to components like "PNL" and
"FIELD" to take full advantage later of the AutoCAD Electrical ability to create
installation or location-specific Bill of Materials and component lists.
Changes the installation codes. Click Browse to
search the active drawing, entire project, and an
Installation
external list (default.inst) for installation codes. Pick
from the list to update the component automatic-
ally with the installation code.
Changes the location codes. Click Browse to search
the active drawing, entire project, and an external
Location
list (default.loc) for location codes. Pick from the
list to update the component automatically with
the location code.
Specifies the Tag ID given to the terminal strip. If
there is an existing name, it appears in the edit box;
if not, you can enter a specific ID name.
Tag Strip
Click the < and > buttons to increment or decre-
ment the last digit/character in the Tag Strip value.
Insert terminals and connectors | 1041