2011

Table Of Contents
Ribbon: Schematic tab Edit Wires/Wire Numbers panel
Fan In/Out - Single line Layer.
Toolbar: Signals
Menu: Wires Signal References Fan In/Out - Single line Layer
Command entry: AEFANIN
Displays only layers that are already assigned as Fan
In/Out Layers as defined in the drawing properties
setup.
Fan-In/Out Line Layers
Picks similar fan-in/out lines from the drawing. You
can use it if the layer of the line is not defined as a
Fan In/Out layer and you want to add it on the fly.
Pick
Changes only the layers of wires that are already
defined as Fan In/Out wires. Otherwise AutoCAD
Change existing wires only (no convert)
Electrical can convert any selected lines to the Fan
In/Out layer.
Changes all the wires to the selected layer that is as-
sociated with the selected wire network. If this option
is not selected, only the selected wire changes.
One pick gets all connected wires
Makes the selected layer the current layer.Make selected layer current
Wire Sequencing
Control from/to report connection sequencing
A wire network consisting of three or more interconnected components
introduces potential unknowns into a from/to connection report. Does A
connect to B and then jumper to C or does C connect to A and jumper to B?
By default, AutoCAD Electrical reports from/to connections on a single network
by first grouping devices by common Location codes and sequentially reports
1026 | Chapter 12 Wire/Wire Number Tools