2011

Table Of Contents
Replaceable parameters for device tagging and wire numbering
Component family code string (ex: "PB", "SS", "CR", "FLT", "MTR")%F
Sheet number of the drawing (ex: "01" entered in upper right)%S
Drawing number%D
Wire layer name of the drawing%G
Sequential or Reference-based number applied to the component%N
Suffix character position for reference-based tagging (not present =
end of tag)
%X
IEC-style project code (default for drawing)%P
IEC-style installation code (default for drawing)%I
IEC-style location code (default for drawing)%L
Project drawing list's SEC value for active drawing%A
Project drawing list's SUB-SEC value for active drawing%B
NOTE If you include %I or %L in the Tag code of the component, you are
prompted to recalculate the tag if you change the Installation or Location value
of the component once it is inserted.
Fix Wire Numbering
Fix wire numbering
Fix a wire number
In some cases, certain wire numbers must be preassigned. They can include
motor wiring that must include special suffix values or other wiring, such as
instrumentation, that might not follow the default numbering convention.
Manually edit the wire number and flip it to fixed. Fixing a wire number
means that the wire number tag is left unchanged if later processed or
reprocessed by the automatic wire numbering utility.
990 | Chapter 12 Wire/Wire Number Tools