Wire connection reports, extracted from the schematic wiring diagrams, can
be formatted and inserted next to panel footprint symbols as simple wiring
tables. AutoCAD Electrical extracts and formats a small report of wire
connection information for the selected components, referencing the wire
extract file. If your footprint symbols carry the AutoCAD Electrical X?TERMxx
attributes, AutoCAD Electrical reports their XYZ wire connection location.
The location is offset by the value defined in Panel Configuration dialog box.
Access:
Click the Panel Reports tool. Select Wire Connection from the report list.
From the Projects menu, select Reports Panel Reports. Select Wire Connection
from the report list.
Specify whether to process the project, active drawing, or a selected component.
Installation Codes to Extract
Extracts only the information for components with specific installation values.
Indicate to process all components that carry part number values, components
without an installation code, or only components marked with a location
code that matches that entered in the edit box. Wild-cards are supported.
After you pick Named Installation, type the installation code in the box or
click List: Drawing or List: Project to select from a list of used installation
codes. You can also create a report from multiple installation codes. AutoCAD
Electrical automatically creates a comma-delimited list for the named
installation search.
Location Codes to Extract
Extracts only the information for components with specific location values.
Indicate to process all components that carry part number values, components
without a location code, or only components marked with a location code
that matches that entered in the edit box. For example, BOM report for
components marked "OP STA 2." Wild cards are supported.
After you pick Named Location, type the location code in the box or click
List: Drawing or List: Project to select from a list of used location codes. You
can also create a report from multiple location codes. AutoCAD Electrical
automatically creates a comma-delimited list for the named location search.
Generate panel reports | 937