2008

Table Of Contents
in the column with the "CMPTAG" label. If there are multiple instances, the
one closest to the PLC I/O point is the one that shows up in the report column.
Access:
Click the Schematic Reports tool. Select PLC I/O Component Connection from
the report list.
From the Projects menu, select Reports Schematic Reports. Select PLC I/O
Component Connection from the report list.
Specify whether to process the project or the active drawing.
Installation Codes to Extract
Extracts only the information for components with specific installation values.
Indicate to process all components that carry part number values, components
without an installation code, or only components marked with a location
code that matches that entered in the edit box. Wild-cards are supported.
Once you pick Named Installation, type the installation code in the box or
click List: Drawing or List: Project to select from a list of used installation
codes. You can also create a report from multiple installation codes. AutoCAD
Electrical automatically creates a comma-delimited list for the named
installation search.
Location Codes to Extract
Extracts only the information for components with specific location values.
Indicate to process all components that carry part number values, components
without a location code, or only components marked with a location code
that matches that entered in the edit box. For example, BOM report for
components marked "OP STA 2". Wild-cards are supported.
Once you pick Named Location, type the location code in the box or click
List: Drawing or List: Project to select from a list of used location codes. You
can also create a report from multiple location codes. AutoCAD Electrical
automatically creates a comma-delimited list for the named location search.
List
Lists drawings that appear to be out-of-date with the project's wire connection
table.
906 | Chapter 14 Reports