5 If this table exists, it is used. If it does not exist, a MISC_CAT table is
looked for if the active projects properties are set up to use this catch-all
table.
6 If all of these items fail, AutoCAD Electrical stops looking (if running a
report) or prompts you to add a table to the default_cat.mdb file (if you
are inserting or editing a component).
If you want your custom symbol to go to table CRM in the catalog database
file instead of the existing table CR you must:
1 Add the WDBLKNAM attribute to your master control relay coil library
symbols with a value of HCRM or VCRM (the orientation does not
matter).
2 Manually add the CRM table in your catalog lookup database file using
Projects Extras Add Table to Catalog Database or Microsoft Access.
NOTE AutoCAD Electrical lways goes to the fixed table names for PLC I/O modules
(PLCIO), terminals (TRMS) and cable markers (W0). Panel layout symbols must
always use the WDBLKNAM attribute or Xdata without the leading H or V character.
Family tables in the default_cat.mdb
The list of tables available in the default_cat.mdb is shown in the following
table. All tables are family-specific and 1 table is created for each family.
DescriptionFamily Code/Table
Name
Allows starting MFG/TYPE/RATING combinations to be predefined
for each catalog lookup table when AutoCAD Electrical would normally
_LISTBOX_DEF
default to the values given in the first record of the selected catalog
lookup table. See Overview of the LISTBOX_DEF catalog database
table (page 788).
Default pin list data table. AutoCAD Electrical also contains manufac-
turer-specific pin list tables that have the same format as the _PINLIST
_PINLIST
table. The naming convention for manufacturer-specific tables is:
_PINLIST_AB or _PINLIST_AROMAT. AutoCAD Electrical first searches
manufacturer-specific tables; if not found, it then searches the default
_PINLIST table. See Use pin lists. (page 793)
768 | Chapter 13 BOM and Catalogs