can leave this field blank if you do not want a
header added to the preview.
Defines the individual terminal block rows in the
table and displays the terminal, wiring, cabling,
Terminal Table Row Block
and terminal destination information. The default
name for the Terminal Table Row Block is TERM-
LAY_ROW.DWG. You can create your own terminal
row symbols by modifying the attribute require-
ments, and then click Browse to search for the new
row block to be used in this tabular terminal strip
layout.
NOTE We do not recommend leaving this option
blank because the table will be empty.
Tabular layout AutoCAD block files insertion points
are required to be in-line with one another in the
Y-axis. AutoCAD Electrical places each symbol in
the drawing at a relative distance based upon the
height of the geometry in the block file.
Specifies the number of rows per section. Dividing
the total number of rows by the rows per section,
Rows Per Section
with the excess falling into the last section, determ-
ines the total number of sections.
Specifies which section to display in the preview
window and then inserts it onto the drawing file.
Section
You can also use the slide control, which breaks the
number of sections into the slide. Slide the arrow
to the appropriate position to change the number
in the input box while updating the preview win-
dow.
Specifies the device tag destination format to be
displayed on either side of the terminal block.
Annotation Format
Updates the Annotation Format fields to reflect the
default allowed replaceable parameters (page 126).
Default Format