2008

Table Of Contents
You can add to the default prefix and suffix list display. Create an ASCII
text file and list each prefix/suffix entry, one per line in the file. Name the
file <projectname>.3ph (where "projectname" is the name of your active
project) or default.3ph and put the file in any folder that is part of AutoCAD
Electrical's search path list.
The wire number assignments go in as Fixed (they will hold the values
that you have assigned and will not retag with a subsequent run of the
Insert Wire Numbers command).
NOTE If this tool does not meet your needs, use the Edit Wire Number tool to
assign fixed wire numbers one at a time.
Automatically insert wire numbers
This tool quickly processes and tags wires on the current drawing, wires in
the project, or individually picked wires.
1 Click the Insert Wire Numbers tool.
2 Select to tag all wires or only new wires.
3 Select to process and tag wires with sequential wire numbers
or with wire numbers based upon the wire network's line ref-
erence location.
4 (Optional) Set other tagging options such as:
specify the wire tag format to use
specify the wire layer format
force all wire numbers to be fixed
update cross-reference text on wire signal source and destination
symbols
update the database for wire signal source and destination symbols
5 Select to tag the selected wires, wires on a drawing, or wires
in a project.
Wire tagging
488 | Chapter 8 Wire/Wire Number Tools