Wire Color/ID
The conductor color code can be manually entered into the edit box or selected
from a generic color pick list. If the parent marker carries a part number, you
can select the next unused color from a used/unused pick list.
Lists the wire colors used for similar cable markers in the current
drawing.
Drawing
Lists the wire colors used for similar cable markers in the project.Project
Description
Up to 3 lines of description attribute text can be entered. These lines are
automatically filled with a copy of the parent's description text if the parent
TAG name is picked using one of the methods above.
Click Pick to copy a description from a cable marker on the current drawing.
Parent cable marker cross-reference
AutoCAD Electrical automatically fills in cross-reference text when the
cross-reference command is run.
Installation Code
Changes the installation codes. You can search the current drawing or entire
project for installation codes. A quick read of all the current or selected drawing
files is done and a list of installation codes used so far is returned. Select from
the list to automatically update the component with the installation code.
Assign short installation codes to components like "PNL" and "FIELD" so you
can take full advantage of the AutoCAD Electrical ability to create
location-specific BOM and component lists later.
Location Code
Changes the location codes. You can search the current drawing or entire
project for location codes. A quick read of all the current or selected drawing
files is done and a list of location codes used so far is returned. Select from
the list to automatically update the component with the location code.
Assign short location codes to components like "PNL" and "FIELD" so you can
take full advantage of the AutoCAD Electrical ability to extract wire and cable
Insert cable markers into wires | 459