2008

Table Of Contents
First, set your project to use automatic fill for Location values, and then set
the default for the drawing. You have a default Location value for each new
component that you insert (whether field or panel) on the same drawing.
1 Click the Project Manager tool.
2 In the Project Manager, right-click the project name, and select
Properties.
3 In the Project Properties Components dialog box, Compon-
ent TAG Options section, select Upon insert: automatic fill
Installation/Location with drawing default or last used. Click
OK.
4 Open the drawing to set the default location value for.
5 Select Projects Drawing Properties.
6 In the Drawing Properties Drawing Settings dialog box,
IEC - Style Designators section, enter a default Location value.
Click OK.
TIP You can click Drawing or Project to select a Location value
that has already been used in either the active drawing or project.
The next time you insert a new component on this drawing,
the Location code are prefilled with the drawing default.
Add a Location code to a saved component
1 Open a saved symbol's .dwg file in AutoCAD.
2 Use the ATTDEF command to add the new attribute or copy an attribute
definition and rename it.
3 Save the drawing file.
The symbol now contains an AutoCAD Electrical Location value attribute.
Add location codes | 415