2008

Table Of Contents
Specifies to reverse or flip only the graphics; component attributes
are not modified.
Graphics only
Swap contact states
This tool flips a contact from one state (open or closed) to the other. It looks
at the picked contact, reads its block name, and checks the 5th character
position for either 1 or 2. It then substitutes 1 or 2 for the found character.
1 Click the Toggle NO/NC tool.
2 Select the component to toggle.
3 (Optional) Type Ctrl + Z to undo the contact swap if you selec-
ted the wrong component.
Existing attribute text is preserved on the flipped contact. If
the maximum contact counts are carried by the parent symbol,
the maximum counts are checked so that they are not exceeded
by the flip.
Check coil/contact count
Using the Cross-Reference Check tool (Components Cross-Reference
Cross-Reference Check), AutoCAD Electrical first extracts a complete list of
components from the project drawing set. Then it prompts you to select a
component to check. AutoCAD Electrical reads the component's tag, finds all
associated components, and lists them in a dialog. It also displays the parent's
assigned catalog number (if one exists) where you can do a catalog check to
see if the item's description indicates that the quantity of contacts can be
accommodated.
Component reference listing
340 | Chapter 6 Component Tools