2008

Table Of Contents
Defines a terminal symbol to be placed into the
spreadsheet on the outer side of the in-line compon-
Include outer terminals
ent (between the I/O component and the wire con-
nected to the ladder rail).
All I/O addresses: Places the terminal symbol
name into the row of every I/O address listed in
the import spreadsheet.
I/O addresses defined: Places the terminal symbol
name into every row where an I/O point is
defined from Unity Pro. The defined address from
Unity Pro is the topographical address coming
from the I/O variable file that contains a value
for the address string.
I/O Variable File
Once you select a module node from the tree selection the data relative to the
I/O variable file displays for viewing and editing. The path and file name of
the I/O variable file created from Unity Pro (.xsy) displays at the top of this
section of the dialog box.
Displays a list of the I/O variables found inside of the
Unity Pro I/O Variable export file (.xsy). This remains
I/O variable file grid
empty if the selected module does not have ad-
dresses (such as power supplies and CPUs).
All I/O points for the respective PLC card display in
the grid (including those that are undefined). The
total number of I/O points and the order of the data
is determined from the topological address in the
.xsy file in combination with the PLC definition inside
of the AutoCAD Electrical PLC database file
(ACE_PLC.MDB).
NOTE Single and multiple row selection is allowed.
Address: Displays the address string from the
Unity Pro I/O Variable export file. This field is not
editable in the dialog box.
Description: Displays the comment field string
associated to the address from the Unity Pro I/O
Create PLC drawings from Unity Pro | 277