2008

Table Of Contents
Module
Specifies the default PLC module style. Select
from the 5 predefined styles or a user-defined
style.
PLC graphical style
Specifies the Input module insertion offset dis-
tance (vertical ladder orientation - measured in
Input offset from neutral
+X direction from right-hand vertical bus; hori-
zontal ladder orientation - measured in +Y direc-
tion from lower horizontal bus).
Specifies the Output module insertion offset dis-
tance (vertical ladder orientation - measured in
Output offset from hot bus
-X direction from the left-hand vertical bus; hori-
zontal ladder orientation - measured in the -Y
direction from the upper horizontal bus).
NOTE If module type cannot be determined or
if it is combination Input and Output, then the
module is inserted down the middle of the lad-
der.
Specifies the maximum number of module I/O
points to insert into each ladder without breaking
the module and continuing it in the next ladder.
Maximum I/O per ladder
Specifies the insertion point offset distance
between one in-line device and the next.
I/O point spacing
Specifies the PLC module scale override value
(default = 1.0). This applies a scale factor to the
Scale
PLC module insertion except for the "Spacing -
I/O point to I/O point" value defined above. If
Apply this scale to module outline only is selec-
ted, then this scaling factor is applied only to the
module's outline.
Overview of the PLC spreadsheet/database format | 265