2008

Table Of Contents
X Zones: Similar to X-Y Grid, but there isn't a Y-axis.
Set your drawing's horizontal labels, spacing, and origin
on the X Zones setup dialog box.
TIP Use a negative zone spacing value if you
want the zone reference origin to be at the right
side of the drawing.
Specifies the width of each ladder (offset distance between
the ladder's 2 bus wires) from left to right rail.
Width
Specifies the offset distance from the insertion point of one
ladder to the insertion point of the next ladder.
Distance between
Specifies the number of ladders to insert. Vertical ladders
insert left to right. Horizontal ladders insert top to bottom.
Ladders per drawing
Specifies the quantity of line reference / wire rungs per
ladder. This value multiplied by the "Spacing - ladder rung
Rungs per ladder
to rung" value determines the length of the inserted lad-
ders.
Specifies the distance from one rung to the next rung on
a ladder.
Rung spacing
Specifies the quantity of rungs to skip before inserting a
PLC module (0=no skip)
Rung count skip for I/O start
Indicates whether to include/exclude bus rails and rungs.Suppression
Specifies the default wire signal arrow style. Select from
the 4 predefined styles or a user-defined style. You can
override the default style setting at insertion time.
Signal arrow style
264 | Chapter 5 PLC