2008

Table Of Contents
PLC Selection Expanded Description Listing Controls
These controls display as an expanded description when the module is
highlighted in the tree structure of the PLC Selection dialog box. These include:
Describes the PLC module being defined.Description
Gives an abbreviated type to the PLC module.Module Type
Specifies whether the PLC module addressing follows an industry
standard. Select from Octal, Decimal, Hexadecimal, and Prompt.
Base Addressing
Prompt asks you at module insertion time for Octal, Decimal, and
Hexadecimal.
Specifies the power rating value for the PLC module.Rating
Specifies the total number of terminals defined on the PLC mod-
ule.
Terminals
NOTE This is not active since it is under the control of the total
number of terminals listed in the Terminal Type grid control.
Specifies the total number of termination points on the PLC
module that will receive the PLC address attributes.
Addressable Points
AutoCAD Block to insert
Specifies an AutoCAD block file to insert directly below the last I/O point
inserted parametrically. These are typically used for block files that represent
DIP switch settings and notes on how to configure the PLC module.
Autolisp file to run at module insertion time
Specifies an AutoCAD Lisp routine to run after the program executes the
parametric build of the PLC module. These are typically used for inserting
groups of symbols and wires, or modifying attributes on symbols to
accommodate a more custom PLC module build.
240 | Chapter 5 PLC