Include unused/extra connections
Specifies to include all of the extra connections to the PLC. Some modules
may have terminals that are not used (i.e. dummy terminals with no electrical
connection). Unused terminals are skipped by default. This results in the most
compact representation of the module, but the PLC modules can be set up to
optionally show unused terminals. This is done by adding in
"\SPECIAL=INCLUDE" and "\SPECIAL=EXCLUDE" flags (in the Attributes
column of the Module Terminal Information table of the ace_plc.mdb file) or
by selecting "When Including Unused" or "When Excluding Unused" in the
Show column of the PLC Database File Editor dialog box.
Insert PLC modules
In AutoCAD Electrical, you can insert either PLC I/O points as independent
symbols or as a complete PLC module into your drawing.
1 Click the arrow on the Insert PLC (Parametric) tool to access
the Insert PLC (Full Units) tool.
2 Click the Insert PLC (Full Units) tool.
3 In the PLC Fixed Units dialog box, select the PLC module to
insert.
4 Specify the insertion point on the drawing.
5 Add or edit any information in the Edit PLC Module dialog
box, and click OK.
Edit PLC module
Use this dialog box when inserting or editing a PLC module. Specify the values
you need and press OK. The values are then annotated onto the selected
module.
Insert PLC modules | 221