2008

Table Of Contents
DescriptionAttribute
second line for a full tag name of "MOT123"). AutoCAD Electrical
pastes the values on these two attributes together when it processes
the component. To include a delimiter character in the tag name but
not show it on the drawing (for example, "MOT-123" but just show
"MOT" and "123"), then a third attribute definition marked invisible,
"TAG1_PARTX" can be added to carry the dash delimiter.
NOTE The default for the %F tagging parameter, as described in
TAG1 above, is carried on the TAG1_PART1 piece of the attribute
pair. If a component with a split tag is marked as Fixed, the attribute
names are automatically changed to "TAG1F_PART1" and
"TAG1F_PART2."
(Child only) Same as above but for child components (64 characters
maximum).
TAG2_PART1
TAG2_PART2
Optional attribute that can carry a copy of whatever AutoCAD Elec-
trical assigns to the tag name attribute - TAG1 or the split tag attribute
combination (64 characters maximum).
COPYTAG
Attribute used to hold manufacturer name or code (24 characters
maximum). This attribute is generally marked as invisible.
MFG
MFG01 - MFG10: Optional invisible attributes for manufacturer name
or code for up to 10 additional "Multiple Catalog" part number as-
signments (24 characters maximum each). If these attributes are not
present and AutoCAD Electrical needs to store the additional part
number information, it is saved on the inserted symbol as Xdata.
NOTE MFG, CAT, and ASSYCODE generally appear on parent com-
ponents only; not child contact symbols.
Attribute used to hold catalog part number assignment (60 characters
maximum). This attribute is generally marked as invisible.
CAT
CAT01 - CAT10: Optional invisible attributes for catalog number code
for up to 10 additional "Multiple Catalog" part number assignments
(60 characters maximum each). If these attributes are not present
and AutoCAD Electrical needs to store the additional part number
information, it will be saved on the inserted symbol as Xdata.
178 | Chapter 4 Symbol Libraries