2008

Table Of Contents
If the WD_PNLM block is not present in a new or existing drawing when
using panel layout symbols, click OK to insert the block.
To force the drawing settings to match the project settings, select the check
box.
Using Layers
Manage layers
AutoCAD Electrical provides tools for managing and renaming panel and
schematic layers.You can use your own layer naming convention with
AutoCAD Electrical, as well as change the layer naming used on an existing
AutoCAD Electrical drawing using the tools below.
Manage panel layers
1 Click the Panel Configuration tool.
2 Click Layers Setup.
3 Specify information for the panel component layers, non-text
graphic layers, and nameplate layers.
When AutoCAD Electrical inserts a footprint, it is modified
on the fly to match the layering scheme set up in this dialog.
4 Click OK.
Rename panel layers
The Rename Panel Layers tool makes it easy to rename layers one by one, or
multiple layers at once by using the Find/Replace method. The advantage to
using the AutoCAD Electrical layer rename is that in addition to renaming
the layer, AutoCAD Electrical also updates the AutoCAD Electrical layer
assignment information carried on the drawing's WD_PNLM block. For
example, if DEMO-PNPG is currently assigned as the Name Plate graphics
layer and you rename it to PNPG using the AutoCAD Electrical rename layer
Using Layers | 143