2008

Table Of Contents
Apply a drawing-specific format settings that are maintained inside the
drawing's WD_M block.
Access:
Click the Project Manager tool. In the Project Manager, right-click the drawing
name, and select Properties Drawing Properties.
From the Projects menu, select Project Project Manager. In the Project
Manager, right-click the drawing name, and select Properties Drawing
Properties.
Ladder Defaults
Specifies whether to create ladders horizontally or
vertically.
Vertical/Horizontal
Specifies the spacing between each ladder rung.Spacing
Sets the default for the Insert Ladder command.New
ladders you insert do not have line reference number-
ing, by default.
Default: insert new ladders without refer-
ences
Specifies the width of the ladder.Width
Specifies the spacing between each wire in multi-wire
phases.
Multi-wire Spacing
Format Referencing
Specifies the default referencing system. There are 3 modes:
All referencing is tied to an X-Y grid system of numbers and letters
along the left-hand side and top of the drawing.Set your drawing's
X-Y Grid
vertical and horizontal index numbers and letters, spacing, and
origin in the X-Y grid setup dialog box.
TIP Use negative spacing values for Horizontal or Vertical if you
want to change the X-Y grid system's origin to be other than the
upper left-hand corner of the drawing.
124 | Chapter 3 Drawing and Project Properties