Apply a drawing-specific component settings that are maintained inside the
drawing's WD_M block.
Access:
Click the Project Manager tool. In the Project Manager, right-click the drawing
name, and select Properties Drawing Properties.
From the Projects menu, select Project Project Manager. In the Project
Manager, right-click the drawing name, and select Properties Drawing
Properties.
Specifies the way new component tags are cre-
ated.The tag consists of a minimum of 2 pieces of
Tag Format
information: a family code and an alphanumeric ref-
erence number (for example, "CR" and "100" to yield
a tag like CR100 or 100CR). Optionally, a component
tag might contain a sheet number or some user-
specified separators. If your format includes the sheet
number %S parameter or the drawing number %D
parameter, you must enter the values in the edit
boxes in the Drawing Properties Drawing Settings
dialog box.
NOTE AutoCAD Electrical provides a predefined
format for you to use or you can enter your own
format using replaceable parameters. (page 126)
NOTE The %N parameter is mandatory in any
component tag format you define.
Searches for a connected PLC I/O module's I/O point.
If found, the I/O address value is substituted for the
"%N" part of the default component tag.
Search for PLC I/O address on insert
NOTE This setting is saved in the MISC_FLAGS attrib-
ute on the drawing's WD_M block.
Enter the beginning sequential number for the
drawing. Sequential tags can continue uninterrupted
Sequential
from one drawing to the next if you assign the same
beginning sequential number to every drawing in
your project. As you insert components on any
Overview of project and drawing properties | 117