2008

Table Of Contents
Components Tab
ing scheme for the active drawing (either sequential
or reference-based).
For sequential numbering, you can enter a starting
number to use as a starting component number.
For reference-based numbering, you can use one
of the following numbering formats:
X-Y Grid
X Zones
Reference Number
Defines most of the specific tagging options to
conform to the IEC tagging mode. Select the option
that best fits your needs:
Component TAG Options
Combined Installation/Location Tag Mode:
Uses the combined installation/location tag for
interpreting component tag names. For ex-
ample, 100CR relay contact marked with loca-
tion code PNL1 is interpreted as being associ-
ated with a different relay coil than relay con-
tact -100CR marked with location code PNL2.
If this setting is not selected, both contacts are
associated with the same parent relay coil, -
100CR.
By selecting this option, your compon-
ent tags are automatically prefixed with
the =, +, and - where applicable.
Suppress dash when first character of tag:
Suppresses any single dash character prefix in
an IEC tag that does not have a leading Install-
ation/Location prefix(i.e. "-K101" dash is sup-
pressed to "K101" but "+LOC1-K101" remains
unchanged.
When switched OFF, it automatically
adds a single dash character to an IEC
tag that does not already have a single
leading dash prefix and does not have
a leading Installation/Location prefix.
For example, tag "K101" becomes "-
Configure projects for various drawing standards | 1245