4 Click OK.
5 Select the appropriate Insert Component command and test your new
symbol insert.
Add an icon to trigger a command
An icon can be configured to trigger an AutoCAD command, trigger an
AutoCAD Electrical command, or run a program. For example, "Rectangle"
can be typed into the edit box so that every time you click the box, it runs
the AutoCAD Rectangle command.
1 On the Icon Menu Wizard dialog box, click Add Command.
NOTE You can also right-click in empty space and select Add icon
Command.
2 On the Add Icon - Command dialog box, specify the name to appear on
the icon and the image file to use on the icon button.
3 Specify the command to execute when the icon button is selected.
Click List to select from a list of AutoCAD Electrical Commands for Panel
and Schematic multi-pole symbol inserts. This makes it easier for you to
build the appropriate command to insert a multipole symbol or a panel
symbol. To see the command line parameters for a specific AutoCAD
Electrical command, select the command in the list and the parameters
display at the right. If quotation marks are shown, then enclose the
parameter value within quotation marks.
NOTE If you select an API command that requires parameters you must
manually enter the additional parameters as indicated. Commands that require
parameters should be inside of parenthesis. If you use one of the AutoCAD
commands from the list, no parenthesis are needed. For example, to add an
icon that will insert a black flush pushbutton, Allen-Bradley, catalog number
800T-A2A, with no rotation, select the command WD_INFP from the list.
When you return to the Command dialog box, you must enter in the rest of
the parameters.
"family" is used for the catalog file lookup table name
"mfg" is used for the footprint lookup
"cat" is the actual catalog number
Add your own symbols, circuits and commands to the icon menu | 1219