2008

Table Of Contents
Modify your project default settings for cross-referencing. Any new drawing
files created within the project are saved with the project default settings for
cross-referencing.
Access:
Click the Project Manager tool. In the Project Manager, right-click the project
name, and select Properties.
From the Projects menu, select Project Project Manager. In the Project
Manager, right-click the project name, and select Properties.
Cross-Reference Format
Defines the cross-reference annotation format. One replaceable parameter,
%N, must always be part of the cross-reference format string. A typical format
string might be just the %N parameter. Use Same Drawing for on-drawing
references and Between Drawings for off-drawing references. You can use the
same format for both.
NOTE AutoCAD Electrical provides some predefined formats for you to use or you
can enter your own format using replaceable parameters. (page 126)
Cross-Reference Options
Automatically updates relay and wire source and
destination symbols cross-referencing across multiple
drawings.
Real time signal and contact cross-referen-
cing between drawings
NOTE If this option is not selected, you are promp-
ted to authorize the update.The target drawing is
automatically opened and updated. You then return
to the active drawing. Any unauthorized update is
queued up in a Project Task List. To update the
pending updates, click Project Task List on the Project
Manager.
Cross-references related components while using
pneumatic features. Example: schematic - pneu-
matic.
Peer to Peer
110 | Chapter 3 Drawing and Project Properties