2008

Table Of Contents
Adding source and destination markers
1 Click the arrow on the Source Destination Signals tool to access
the Fan In/Out Source tool.
2 Click the Fan In/Out Source tool.
3 In the Fan In/Out Source dialog box, select Solid as the Source
marker style.
4 Click the left button to set the wire connection orientation.
5 Select in the middle of the wire that is connected to the top
push button.
6 In the Signal - Source Code dialog box, enter "cbla" as the code
and "RED" as the description.
If you enter the color of the wire in the Description field,
AutoCAD Electrical reports use this information in the Wire
Color field.
7 Click OK.
8 In the Source/Destination Signal markers (for Fan In/Out)
dialog box, click Yes to insert the matching destination marker
now.
NOTE Since the destination wires are nearby it's easier to insert
them right away. If the wires were on another drawing you could
wait until later to add the destination markers.
9 In the Fan-In/Fan-Out Signal Destination dialog box, select
Solid as the destination marker style.
10 Click the right button to set the wire connection orientation.
11 Select in the middle of the wire connected to the top limit
switch.
Notice that the wires for both change from blue to red and
Show source and destination markers on cable wires | 1201