5 On the Project Manager, double-click the instrument drawing to open
it.
6 Zoom in so that your valve representation is visible.
7 On the Project Manager, right-click the project name, and select
Properties.
8 On the Project Properties, Cross-References dialog box, Cross-Reference
Options section, select Peer-to-Peer.
9 Click OK.
10 Right-click the schematic symbol to edit in the drawing (in this case,
SOL2500).
11 Select Edit Component from the context menu.
12 On the Insert/Edit Component dialog box, click Tags Used: Schematic.
13 Select Show all components for all families.
The tag values from the other symbol are displayed in the list.
14 Select the valve representation (in this case, FE100) with a family code
of IN (for instrument).
15 Click Copy Tag.
16 On the Copy Tag dialog box, click WDTAGALT.
17 On the Insert/Edit Component dialog box, click Show/Edit Miscellaneous.
18 Verify that the WDTAGALT value lists the valve's TAG1 value (in this
case, FE100) and click OK.
19 On the Insert/Edit Component dialog box, click OK.
20 On the Update Other Drawings dialog box, click Now to update the
drawing.
Set up peer-to-peer component relationships | 1189