Displays duplicated schematic terminal numbers. The report
lists the terminal tag id and duplicated terminal number,
Terminal Duplication
reference of the terminal number, error message, and the
drawing where the error occurs.
NOTE Terminal numbers listed in WDN files (located in
the same folder as the project definition file (*.wdp)) are
not checked for duplications. You can use wildcards to ex-
clude a range of terminals for duplication checking making
use of this text file.
Displays duplicated component pin assignments. The report
lists the schematic component reference designation tag
Pin Exception
and component wire connection pin, reference of the
component tag, error message, and the drawing where
the error occurs.
Displays any children without a parent schematic compon-
ent. The report lists the component reference designation
Contacts
tag for the child without a parent, reference of the child
component tag, error message, and the drawing where
the error occurs.
Displays the recovery tip so that you can fix the error.Recovery Tip
Goes to the error location within the project and correct
the error. This is enabled when you select a single audit
Go To
record in the dialog box. Once you browse to an error
location an "x" appears in the left-hand column of the
Electrical Audit dialog box.
NOTE You can also double-click an audit record to go to
the error location.
Saves the audit report. Save As saves only the active report
while Save All saves the complete audit report.
Save As/Save All
Prints the audit report.Print
Drawing audit
1182 | Chapter 18 Miscellaneous Tools