2008

Table Of Contents
found. Click Details to view the detected problems, and then go to the error
location within the project and correct the error.
Access:
Click the arrow on the Schematic Reports tool to access the Electrical Audit tool.
From the Projects menu, select Reports Electrical Audit.
Displays the unconnected wires for the active project. The
report lists the unconnected wire number, location point,
Wire - No Connection
error message, and the drawing where the error occurs. If
there isn't a record of a wire number, the wire number
column is blank.
Displays missing or duplicated wire numbers for the active
project. The report lists the duplicated wire number, error
Wire Exception
message, and the drawing where the error occurs. If a wire
number is missing, the wire number column is blank.
Displays the duplicated cable and wire id for the active
project. The report lists the duplicated cable tags or cable
Cable Exception
tags with duplicated wire id, error message, reference of
the cable tag, and the drawing where the error occurs.
Displays components with no bill of material part assign-
ments. The report lists the component reference designa-
Component - No Catalog Number
tion tag, reference of the component tag, error message,
and the drawing where the error occurs.
Displays the duplicated schematic/panel components. The
report lists the schematic/panel component reference des-
Component Duplication
ignation tag, reference of the component tag error mes-
sage, and the drawing where the error occurs.
Displays component connections with no connected wires.
The report lists the component reference designation tag,
Component - No Connection
reference of the component tag, error message, and the
drawing where the error occurs.
Overview of real-time error checking | 1181