2008

Table Of Contents
Specifies the source or load value to save on the connection point.Value
(Optional) Specifies the units for the source or load value. Select
from the drop-down list to specify the units.
Units
Potential assignment
Optional for voltage level mismatch checks. Select from the drop-down list
to specify the potential value.
Set pass power
This utility marks a component with a PASSPWR flag. The PASSPWR flag
instructs the Power Report to pass through the marked component when
calculating the load on a given source. If a component carries the PASSPWR
flag the Power Report program will pass through the component and continue
looking for load values on the network.
NOTE Certain components don't need a PASSPWR flag (such as terminals and
contacts) since they are automatically 'passed' through.
Access:
On the Power Check toolbar, click the Mark Component To Pass Power tool.
Click Wires Wire Number Miscellaneous Power Check Mark Com-
ponent To Pass Power.
Each selected component is displayed in the list. If the component already
carries the PASSPWR flag, a * appears next to the tag. To set or unset the
PASSPWR flag, click on the component's tag in the list.
Power source/load report
Once a component is marked with a power source and load value, this utility
scans the wire interconnections and reports if there is too much load on a
given power source.
Access:
On the Power Check toolbar, click the Power Load Check Report tool.
Click Wires Wire Number Miscellaneous Power Check Power Load
Check Report.
1160 | Chapter 18 Miscellaneous Tools